Product Overview
Overview
The CF2001 series absolute/pressure transmitter uses high-precision and high stability diffusion silicon isolation sensor components. Through highly reliable amplification circuits and precise temperature compensation, the absolute or gauge pressure of the measured medium is converted into a 4-20 mA DC standard electrical signal. The packaging technology and sophisticated assembly process ensure the excellent quality and performance of the product. This product has the characteristics of complete variety specifications, standardized interface forms, and convenient zero and range adjustment, which can meet the needs of customers to the fullest extent.
The CF2001 series of absolute pressure/pressure transmitter products are divided into three types: ordinary type, intrinsic safety explosion-proof type, and explosion-proof type. Intrinsic safety explosion-proof and explosion-proof products can be widely used in various harsh and dangerous places in industrial sites.
characteristics
Minimum measurement range above 5 K Pa
Measurement range 0-3 2 M P a
Direct process connection does not require installation of brackets
Zero point and external continuous adjustable range
Lightning protection and radio frequency interference prevention
With on-site instructions
Intrinsically safe explosion-proof or flameproof
Small size, beautiful appearance, high cost-effectiveness
High precision, high stability, high reliability
Optional H A R T communication protocol overload pressure
2 times the range or 70 M P a (take the minimum value)
output signal
4-20 m A D C (two-wire system)
Working Voltage
14-36V DC (two-wire system) standard 24V DC ± 5%, ripple less than 1%
medium temperature
- 2 5 ~+ 1 0 0℃
ambient temperature
- 2 0℃~+ 8 5℃
relative humidity
0 %~99%
Application
Industrial field liquid level measurement and control
Laboratory pressure calibration system
Navigation and shipbuilding
Aviation and Aircraft Manufacturing
Air separation equipment and thermal power units
Energy Management System
Liquid level measurement and water supply system
Hydraulic and Pneumatic Control System
technical indicators
measuring medium
Various liquids, gases, or vapors compatible with 316L stainless steel
range
0-5 K P a to 0-3 2 M P a (see selection table) Load resistance
(4~2 0 m A) :R =(U-14)0.02-R0
Among them: U is the power supply voltage, R0 is the internal resistance of the cable
(0~1 0 m A) :R≤1 KΩ
(0~5 V) :R≥3 0 0Ω
Performance refers to standard accuracy
± 0.1% (including comprehensive errors such as nonlinearity, repeatability, and hysteresis)
zero shift
Positive shift: 0% to+80% of the range Negative shift: 0% to -99% of the range (not exceeding -100KPa, no negative shift for absolute pressure products)
Range adjustment
Adjust the minimum range to any range (see selection table)
Overvoltage impact
Less than 0.25% of the range
Power supply impact
Less than 0.01% V of the output range
Load impact
negligible
temperature effect
± 1.5% of the measuring range (temperature range: -20 to+85 ℃, including the total temperature impact of zero and measuring range)
stability
± 0.25%/year of range, structural characteristics, materials
316L stainless steel diaphragm
Joint material
316 stainless steel
housing material
Surface spray treatment of cast aluminum alloy
process interface
M20 × 1.5, NPT1/2 or G1 external thread (large opening)
electrical interface
Standard waterproof plug
NPT1/2 internal thread cable sealing joint
instruction table
M3 digital LCD display head
weight
About 1 2 k g
Explosion-proof marking
Exia Ⅱ CT5 (Ben An type) Exd Ⅱ CT5 (explosion-proof type)
The overall protective performance meets the requirements