CF2002 intelligent integrated transmitter

★★★★★ 4.9/5 (156 reviews)

Product Overview

Overview

The integrated absolute/pressure transmitter uses high-precision and high stability diffusion silicon isolation sensor components, which convert the absolute or gauge pressure of the measured medium into a 4-20mADC standard electrical signal through highly reliable amplification circuits and precision temperature compensation. The packaging technology and sophisticated assembly process ensure the excellent quality and performance of the product. This product has the characteristics of complete variety specifications, standardized interface forms, and convenient zero and range adjustment, which can meet the needs of customers to the fullest extent.

The CF2002 integrated transmitter series can be widely used in various harsh and dangerous places in industrial sites.

characteristics

Minimum measurement range above 5KPa

Measurement range: 0-32MPa

Direct process connection does not require installation of brackets

Zero point and external continuous adjustable range

Lightning protection and radio frequency interference prevention

With on-site instructions

Intrinsically safe explosion-proof or flameproof

Small size, beautiful appearance, high cost-effectiveness

High precision, high stability, high reliability overload pressure

2 times the range or 70 M P a (take the minimum value)

output signal

4-20 m A D C (two-wire system)

Working Voltage

14-36 (two-wire system) standard 24VDC ± 5%, ripple less than 1%

medium temperature

- 2 5~+ 1 0 0℃

ambient temperature

- 2 0~+ 8 5℃

relative humidity

0 %~1 0 0 %

Application

Industrial site process pressure detection and control

Laboratory pressure calibration system

Navigation and shipbuilding

Aviation and Aircraft Manufacturing

Air separation equipment and thermal power units

Energy Management System

Liquid level measurement and water supply system

Hydraulic and Pneumatic Control System

technical indicators

measuring medium

Various liquids, gases, or vapors compatible with 316L stainless steel

range

0-5 K P a to 0-3 2 M P a (see selection table) Load resistance

(4~20 m A) :R =(U-14)0.02-R0

Among them: U is the power supply voltage, R0 is the internal resistance of the cable

(0~10 m A) :R≤1KΩ

(0~5V) :R≥300Ω

Performance refers to standard accuracy

±0 . 1% (including comprehensive errors such as nonlinearity, repeatability, and hysteresis)

zero shift

Positive migration: 0% to+80% of the range Negative migration: 0% to -100% of the range (not exceeding -100 K Pa absolute pressure products without negative migration)

Range adjustment

Adjust the minimum range to any range (see selection table)

Overvoltage impact

Less than the range of 0  2 5 %

Power supply impact

Less than 0 of the output range  0 1 % V

Load impact

negligible

temperature effect

± 1 of the measuring range 5% (temperature range: -20 to+85 ℃, including the total temperature impact of zero and range)

stability

± 0 of the measuring range 2 5%/year structural characteristics membrane material

316L stainless steel

Joint material

1Cr18Ni9Ti stainless steel

housing material

1Cr18Ni9Ti stainless steel

process interface

M20 × 1.5, NPT1/2 or G1 external thread (large opening)

electrical interface

Standard waterproof plug

instruction table

nothing

weight

About 1.2kg

Explosion-proof marking

Exia Ⅱ CT5 (Ben An type) Exia Ⅱ CT5 (Explosion proof type)

The overall protective performance meets the following requirements:

IP67 (compliant with relevant parameters)