Horizontal fuel thermal oil furnace

★★★★★ 4.9/5 (156 reviews)

Product Overview

Product Introduction

The horizontal fuel thermal oil furnace is an assembled boiler, and only the system equipment and pipelines need to be connected during boiler installation. The design of integrated boilers makes installation more convenient and efficient. This boiler adopts intelligent control, making boiler operation particularly convenient and simple. The controller is a simulated screen display, centrally controlled by the processor, and has functions such as automatic ignition and shutdown program control, automatic combustion control, automatic switching and control of the circulating pump, automatic fault handling and alarm.

Product Introduction

The horizontal fuel thermal oil furnace is an assembled boiler, and only the system equipment and pipelines need to be connected during boiler installation. The design of integrated boilers makes installation more convenient and efficient. This boiler adopts intelligent control, making boiler operation particularly convenient and simple. The controller is a simulated screen display, centrally controlled by the processor, and has functions such as automatic ignition and shutdown program control, automatic combustion control, automatic switching and control of the circulating pump, automatic fault handling and alarm. 

Characteristics of gas (oil) hot oil furnace:

1. Able to achieve higher working temperature under lower operating pressure. 

2. Stable heating and precise temperature can be achieved. 

3. The thermal efficiency can be maintained at * level under various levels of load. 

4. Liquid phase transport of thermal energy, with a heat carrier that has a saturated vapor pressure 70 times lower than water at 300 ℃. 

5. It has complete operation control and safety monitoring devices. 

6. Energy saving, fuel saving, water saving, and cost saving, with investment recovery in 3-6 months

Regulations for Horizontal Fuel Thermal Oil Furnace:

Pre start inspection

1. Check whether the heating furnace and its surroundings are clean and free of debris, and whether the furnace body, burner, controller, sight hole, chimney, etc. are normal 

2. Reverse the process equipment and flow, check whether the oil level in the expansion tank is above the 1/4-1/2 liquid level, and whether the thermometer, pressure gauge, etc. are normal 

3. Connect the power supply of the heating furnace control cabinet, check if the voltage is normal, and check if the indicator lights and various display instruments are normal 

4. Adjust the gas main pressure reducing valve and secondary pressure reducing valve to control the pressure to 0.005 MPa. 

Start up

1. Start the heat transfer oil circulation pump (one in operation and one as backup, follow the water pump operating procedures), and circulate normally for about 0.5 hours after starting the pump to stabilize the pressure; 

2. Press the burner start button and observe whether the furnace flame is burning normally. If it does not ignite, the burner should be restarted after troubleshooting